Ten reference working capacities from 50 to 5000 L


Example installation with two vessels, a platform and a control panel; capacity, vessel quantity and supply scope are defined in the quotation.
Mixing and process reactors
Stainless steel mixing reactor with working capacities from 50 to 5000 L
10 reference working capacities: 50–5000 L; project-specific configuration
Stainless steel mixing reactor/tank for preparing and blending chemicals and liquid formulations, including liquid fertilisers where the composition is compatible. The agitator moves the product to incorporate components and distribute the mixture through the vessel. Its geometry is selected for viscosity and the operation, with anchor, turbine or scraping options and high-shear mixing when specified. In jacketed versions, a thermal circuit allows heating or cooling to suit the process. The range offers reference working capacities from 50 to 5000 L, with materials, agitation, heating and connections defined for each project and its intended formulation.
Agitator selected for viscosity and the operation
304 or 316L stainless steel options and project-specific thermal construction
Technical data
Reference configuration
The final configuration is selected for the intended operation, installation conditions and compatibility with existing equipment.
Reference working capacities: 50–500 L
Each column identifies a model or configuration. Shared values are marked.
↔ Scroll to compare models
| Parameter | 50 L | 100 L | 200 L | 300 L | 500 L |
|---|---|---|---|---|---|
| Working capacity stated in the table | 50 L | 100 L | 200 L | 300 L | 500 L |
| Mixing power in the reference table | 0.75 kW | 1.1 kW | 1.1–2.2 kW | 1.5–2.2 kW | 4–5.5 kW |
| Mixing speed in the reference table | 0–63 rpm | 0–63 rpm | 0–63 rpm | 0–63 rpm | 0–63 rpm |
| Heating method in the reference table | Electric | Electric | Electric | Electric | Electric |
| Total vessel volume | — | — | — | — | — |
| Net assembly weight | — | — | — | — | — |
| Overall dimensions (L × W × H) | — | — | — | — | — |
| Final configuration voltage | — | — | — | — | — |
| Supply phases and frequency | — | — | — | — | — |
| Heating power | — | — | — | — | — |
| Total installed electrical power | — | — | — | — | — |
| Permissible operating temperature | — | — | — | — | — |
| Pressure and vacuum limits | — | — | — | — | — |
— To be confirmed for this configuration.
Capacities are identified as working capacities, not nominal or total vessel volumes. Reference-table values are subject to the final configuration. Power ranges represent mixing-drive sizing options, not continuously adjustable electrical power, total consumption or heating power. Speed applies to the reference agitation, not any optional high-shear drive. Heating methods are configuration alternatives; thermal ratings, electrical supply, materials and accessories are defined for the project.
Reference working capacities: 1000–5000 L
Each column identifies a model or configuration. Shared values are marked.
↔ Scroll to compare models
| Parameter | 1000 L | 1500 L | 2000 L | 3000 L | 5000 L |
|---|---|---|---|---|---|
| Working capacity stated in the table | 1000 L | 1500 L | 2000 L | 3000 L | 5000 L |
| Mixing power in the reference table | 4–7.5 kW | 5.5–7.5 kW | 5.5–7.5 kW | 11–15 kW | 18.5–22 kW |
| Mixing speed in the reference table | 0–63 rpm | 0–63 rpm | 0–63 rpm | 0–63 rpm | 0–63 rpm |
| Heating method in the reference table | Electric or steam, selected for the configuration | Electric or steam, selected for the configuration | Electric or steam, selected for the configuration | Electric or steam, selected for the configuration | Electric or steam, selected for the configuration |
| Total vessel volume | — | — | — | — | — |
| Net assembly weight | — | — | — | — | — |
| Overall dimensions (L × W × H) | — | — | — | — | — |
| Final configuration voltage | — | — | — | — | — |
| Supply phases and frequency | — | — | — | — | — |
| Heating power | — | — | — | — | — |
| Total installed electrical power | — | — | — | — | — |
| Permissible operating temperature | — | — | — | — | — |
| Pressure and vacuum limits | — | — | — | — | — |
— To be confirmed for this configuration.
Capacities are identified as working capacities, not nominal or total vessel volumes. Reference-table values are subject to the final configuration. Power ranges represent mixing-drive sizing options, not continuously adjustable electrical power, total consumption or heating power. Speed applies to the reference agitation, not any optional high-shear drive. Heating methods are configuration alternatives; thermal ratings, electrical supply, materials and accessories are defined for the project.
Range options selected per project
| Material options | 304 or 316L stainless steel; selected for each component and product |
|---|---|
| Range construction options | Single layer; double layer for heating; or three layers with insulation, according to configuration |
| Agitator options | Impeller, anchor, turbine, high-shear, magnetic or anchor-with-scraper mixing; selected per project |
| Heat-transfer jacket options | Full jacket, dimple jacket or coil; circuit and utilities defined for the configuration |
| Voltage options by configuration | Project-selected voltage within the stated 110–480 V range; final supply to be defined |
Project and supply
Configured for your process
Before the proposal, we confirm the application, operating parameters, interfaces and scope of supply.
- Technical selection and configuration
- Documentation and automation options
- Delivery to Europe, North America and South America